Every CAD file, STEP model, cut sheet, and product spec for the full JET Filter™ and GEOJET line, free to download for your design and submittal work. Here is what is in the library and how to put it to work.
When you are detailing weep hole drainage on a retaining wall, seawall, abutment, or culvert, you need accurate geometry and verified performance data, not a sales brochure. The JET Filter™ Engineering Hub gives you both: downloadable CAD and STEP files for every model, cut sheets with real dimensions, and product specifications backed by independent testing. This guide walks through what is available, what each file type is for, and how engineers use the library from concept through submittal. Prefer to talk it through? Request information and our technical team can help.
What Is in the Engineering Library
The Engineering Hub hosts a complete technical documentation set for all 13 JET Filter™ and GEOJET models. Each model has its own download package so you can pull only the files relevant to your project.
Four File Types, One Download
Cut Sheets. Dimensioned drawings with imperial and metric measurements, ready to reference in a plan set or detail callout.
Product Specs. Material grades, tested flow rates, filter fabric surface area, and recommended maintenance intervals for each model.
CAD Files. 2D drawing files for placement into your construction documents and detail sheets.
STEP Files. 3D solid models for BIM and 3D modeling environments, so the unit drops into your project geometry at the correct scale.
Alongside the per-model packages, the Hub includes application installation guides and detail drawings for sheet piling, concrete seawalls and bulkheads, bridge abutments and wing walls, MSE retaining walls, trapezoidal lined channels, and box culverts, plus French drain details for highway and waterfront walls.

Cut sheets include dimensioned geometry in both imperial and metric units for every model.
How Engineers Use These Files
The library is organized around the engineering workflow, from early design through the submittal a contractor hands to the owner for approval.
Concept and sizing. Use the product specs to match a model to your design drainage rate and retained soil. Flow rate and filter fabric surface area drive the selection.
Detailing. Drop the CAD file into your wall, abutment, or culvert detail and reference the cut sheet dimensions in your callouts.
3D and BIM coordination. Import the STEP file to confirm fit at penetrations and coordinate with reinforcing and other embeds.
Submittal. Package the cut sheet, product spec, and compliance documentation for owner and DOT review.
The Complete Model Lineup
Thirteen models cover sizes from 2.5 inch to 6 inch, with check valve (CVLV) options for tidal and backflow applications. JET Filter™ models carry tested flow data; GEOJET models, engineered for hydrocarbon capture, carry estimated rates extrapolated from JET Filter testing.
| Model | Size | Flow (1 PSI, No Soil) | Surface Area | Cartridge Interval | Material |
|---|---|---|---|---|---|
| JF3SS | 3″ | 33 GPM | 17.44 in² | 3–5 yrs | 316L SS |
| JF3SSCVLV | 3″ | 26.6 GPM | 17.44 in² | 3–5 yrs | 316L SS + valve |
| JF4SS | 4″ | 77.1 GPM | 26.03 in² | 4–7 yrs | 316L SS |
| JF4SSCVLV | 4″ | 66.5 GPM | 26.03 in² | 4–7 yrs | 316L SS + valve |
| JF6SS | 6″ | 166.6 GPM | 76.95 in² | 6–10 yrs | 316L SS |
| JF6SSCVLV | 6″ | 162.3 GPM | 76.95 in² | 6–10 yrs | 316L SS + valve |
| JF2.5ABS | 2.5″ | Not tested | 2.9 in² | Annually | ABS Plastic |
| GEO3SS | 3″ | 34.7 GPM† | 17.44 in² | 1–3 yrs‡ | 316L SS |
| GEO3SSCVLV | 3″ | 30.5 GPM† | 17.44 in² | 1–3 yrs‡ | 316L SS + valve |
| GEO4SS | 4″ | 71.3 GPM† | 26.03 in² | 1–3 yrs‡ | 316L SS |
| GEO4SSCVLV | 4″ | 65.6 GPM† | 26.03 in² | 1–3 yrs‡ | 316L SS + valve |
| GEO6SS | 6″ | 154.1 GPM† | 76.95 in² | 1–3 yrs‡ | 316L SS |
| GEO6SSCVLV | 6″ | 150.1 GPM† | 76.95 in² | 1–3 yrs‡ | 316L SS + valve |
JET Filter™ flow rates at 1 PSI, No Soil conditions per TRI Environmental Report MAPP-LSH 2020-003. †GEOJET rates are estimates extrapolated from JET Filter test data and are not directly tested. ‡GEOJET media replacement interval varies with hydrocarbon loading. Housing service life is 100+ years for all 316L stainless steel models. Full per-model data and downloads are available through the Engineering Hub.
The Standards Behind the Spec Sheets
The spec sheets reference the test standards used to validate each component, so you can cite verified performance in your documentation rather than unsupported manufacturer claims.
| Standard | What It Tests | Applies To |
|---|---|---|
| ASTM A240 / A666 | Stainless steel plate, sheet, and strip specifications | 316L stainless steel housing (all SS and CVLV models) |
| ASTM D4491 | Water permeability of geotextiles | Replaceable geotextile filter cartridge |
| ASTM D4751 | Apparent opening size (AOS) of geotextile | Replaceable geotextile filter cartridge |
Steel standards apply to 316L stainless steel models only. Geotextile standards apply to the replaceable filter cartridge. Full test documentation is available through the Engineering Hub.
Get the Files You Need for Your Next Design
CAD files, STEP models, cut sheets, product specs, and compliance documentation for all 13 models are available through the Engineering Hub at no cost.
DOT Approved. Buy America compliant. US Patents #7,615,148 (open end) and #10,124,281 (check valve).